• China Made Factory Supply Electric Heating Cable for Water Supply Pipes of Commercial Houses
  • China Made Factory Supply Electric Heating Cable for Water Supply Pipes of Commercial Houses
  • China Made Factory Supply Electric Heating Cable for Water Supply Pipes of Commercial Houses
  • China Made Factory Supply Electric Heating Cable for Water Supply Pipes of Commercial Houses
  • China Made Factory Supply Electric Heating Cable for Water Supply Pipes of Commercial Houses
  • China Made Factory Supply Electric Heating Cable for Water Supply Pipes of Commercial Houses
  • China Made Factory Supply Electric Heating Cable for Water Supply Pipes of Commercial Houses
  • China Made Factory Supply Electric Heating Cable for Water Supply Pipes of Commercial Houses
  • China Made Factory Supply Electric Heating Cable for Water Supply Pipes of Commercial Houses
  • China Made Factory Supply Electric Heating Cable for Water Supply Pipes of Commercial Houses

China Made Factory Supply Electric Heating Cable for Water Supply Pipes of Commercial Houses

  • China Made Factory Supply Electric Heating Cable for Water Supply Pipes of Commercial Houses
  • China Made Factory Supply Electric Heating Cable for Water Supply Pipes of Commercial Houses
  • China Made Factory Supply Electric Heating Cable for Water Supply Pipes of Commercial Houses
  • China Made Factory Supply Electric Heating Cable for Water Supply Pipes of Commercial Houses
  • China Made Factory Supply Electric Heating Cable for Water Supply Pipes of Commercial Houses
Description

China Made Factory Supply Electric Heating Cable for Water Supply Pipes of Commercial Houses

 China Made Factory Supply Electric Heating Cable for Water Supply Pipes of Commercial HousesChina Made Factory Supply Electric Heating Cable for Water Supply Pipes of Commercial Houses

 

The structure of the self-regulating electric heating cable is composed of a core, a core strip, an insulation, a shielding layer, a sheath. The voltage by classification includes voltage levels of 12V, 24V, 36V, 110V, 220V, 380V, etc.; the classification by production materials include ordinary type electric heating cable, flame-retardant electric heating cable (flame-retardant core belt, flame-retardant insulation, flame-retardant sheath) and Fluorine material electric heating cable (fluorine material core belt, fluorine material insulation, fluorine material sheath); for application classification, including civil solar energy, industrial, geothermal heating, fire protection, thermal oil recovery, etc.

 

Technical Parameter of different types of self-regulating cable and advantages

 

Low temperature series Intermedium temperature series

(1) Standard color: black / blue

(2) Temperature range: the maximum maintenance temperature is 65±5°C, and the maximum temperature is 90°C (the core belt withstands)

(3) Construction temperature: polyolefin minimum -40 ° C, fluorine material minimum -30 ° C

(4) Starting current: ≤0.5A/m

(5) Thermal stability: After the thermal performance test of the electric heating cable, its power should be maintained at 90% of the original value.

(6) Bending radius: 25.4mm at -20°C and 35mm at -30°C

(7) Insulation resistance: The insulation resistance between the electric heating conductor and the metal shield should not be less than 500 MΩ.

(1) Standard color: brown

(2) Temperature range: the maximum maintenance temperature is 90±5°C, and the maximum temperature is 125°C (the temperature that the core belt withstands)

(3) Construction temperature: polyolefin minimum -40 ° C, fluorine material minimum -30 ° C

(4) Starting current: ≤0.6A/m

(5) Thermal stability: After the thermal performance test of the electric heating cable, its power should be maintained at 90% of the original value.

(6) Bending radius: 30.4mm at -20°C and 40.6mm at -30°C

(7) Insulation resistance: The insulation resistance between the electric heating conductor and the metal shield should not be less than 500 MΩ.

 

 

 

                 High temperature series                           Advantages

(1) Standard color: red

(2) Temperature range: the highest maintenance temperature is 125±5°C, and the maximum temperature is 160°C (the temperature that the core belt withstand)

(3) Construction temperature: polyolefin minimum -40 ° C, fluorine material minimum -30 ° C

(4) Starting current: ≤0.9A/m

(5) Thermal stability: After the thermal performance test of the electric heating belt, its power should be maintained at 90% of the original value.

(6) Bending radius: 38.5mm at -20°C and 49mm at -30°C

(7) Insulation resistance: The insulation resistance between the electric heating conductor and the metal shield should not be less than 500 MΩ.

(1) Automatically adjust the output power and compensate according to the actual heat required by the heat tracing system, which is a new generation of energy-saving constant temperature heater.
(2) It can be arbitrarily shortened or extended within a certain range, and it can be overlapped multiple times without the concern of high temperature hot spots and burnout.
(3) Low temperature, fast start, uniform temperature, because each part can be automatically adjusted due to the temperature change of the heat-tracing place.
(4) Easy installation, simple maintenance, all-day service, high level of automation, and low operating and maintenance costs.
(5) It is safe and reliable, widely used, no polluation to the environment, long service life.